| Capacity | V/Hz | SKU | Price |
|---|---|---|---|
| 11.9 Cu ft. | 115V / 60 Hz | HAR:DW-86L338J |
$9,598
|
| 20.4 Cu ft. | 115V / 60 Hz | HAR:DW-86L578J |
$11,997
|
| 20.4 Cu ft. | 220V / 60 Hz | HAR:DW-86L578JA |
$11,997
|
| 25.7 Cu ft. | 115V / 60 Hz | HAR:DW-86L728J |
$13,597
|
| 25.7 Cu ft. | 220V / 60 Hz | HAR:DW-86L728JA |
$13,597
|
| 29.3 Cu ft. | 115V / 60 Hz | HAR:DW-86L828J |
$14,397
|
| 29.3 Cu ft. | 220V / 60 Hz | HAR:DW-86L828JA |
$14,397
|
Haier Biomedical’s standard range of Salvum low energy ultra-low temperature freezers, with innovative cabinet design to reduce energy consumption, provides reliable performance whilst reducing operational noise.
Features:
NOTE: There is an 8 week lead time for these freezers.
Rack and box accessory orders can only be placed at time of freezer purchase. We apologize for any inconvenience this may cause.
|
Min. Temperature |
-40~-86°C |
|
Cubic Feet |
11.9 to 29.3 |
|
Alarms |
Yes |
|
Controls |
Digital |
|
Defrost |
Manual |
|
Electrical |
115V OR 220V, 60 Hz |
|
Warranty (years) |
3 years (+ 2 additional years parts only on compressor) |
|
Weight (lb) |
723 to 838 |
|
Width (in) |
32 to 45.1 |
|
Depth (in) |
35.2 to 35.4 |
|
Height (in) |
72.7 to 78 |
| Model | DW_86L338J | DW-86L578J(A) | DW-86L728J(A) | DW-86L828J(A) |
| Product | -86℃ ULT Freeer | -86℃ ULT Freeer | -86℃ ULT Freeer | -86℃ ULT Freeer |
| Cabinet Type | Upright | Upright | Upright | Upright |
| Climate Class | N | N | N | N |
| Cooling Type | Direct cooling | Direct cooling | Direct cooling | Direct cooling |
| Defrost Mode | Manual | Manual | Manual | Manual |
| Refrigerant | HC | HC | HC | HC |
| Noise Level (db) | 50 | 50 | 50 | 50 |
| Cooling performance(℃) | -86 | -86 | -86 | -86 |
| Temperature Range(℃) | -40~-86 | -40~-86 | -40~-86 | -40~-86 |
| Controller | Microprocessor | Microprocessor | Microprocessor | Microprocessor |
| Display | LED | LED | LED | LED |
| Power Supply(V/Hz) | 220V/60 | 115V OR 220V/60 | 115V OR 220V/60 | 115V OR 220V/60 |
| Power(W) | 900 | 900 | 1000 | 1000 |
| Electrical Current(A) | 7.5 | 9 | 10 | 10 |
| Capacity(L/Cu.Ft) | 338/11.9 | 578/20.4 | 728/25.7 | 828/29.2 |
| Net/Gross Weight(approx) | 238/278(kg) 524.7/612.9(lbs) | 300/330(kg) 661.4/727.5(lbs) | 345/385(kg) 760.6/848.8(lbs) | 380/410(kg) 837.8/903.9(lbs) |
| Interior Dimensions(W*D*H) | 465*630*1165 18.3*24.8*45.9 | 620*716*1310(mm) 24.4*28.2*51.6(in) | 766*716*1310(mm) 27.0*28.2*51.6(in) | 870*716*1310(mm) 34.3*28.2*51.6(in) |
| Exterior Dimensions(W*D*H) | 812*893*1846 32.0*35.2*72.7 | 895*980*1960(mm) 35.4*38.6*78.0(in) | 1041*980*1980(mm) 36.7*38.6*78.0(in) | 1145*980*1980(mm) 45.1*35.4*78.0(in) |
| Packing Dimensions(W*D*H) | 875*970*2010 34.4*38.2*79.1 | 950*1055*2125(mm) 37.4*41.5*83.7(in) | 1090*1050*2150(mm) 42.9*41.3*84.6(in) | 1190*1045*2150(mm)46.9*41.1*84.6(in) |
| Container load (20'/40'/40'H) | 12/24/24 | 12/24/24 | 12/20/20 | 8/20/20 |
| High/Low Temperature | Y | Y | Y | Y |
| Remote Alarm | Y | Y | Y | Y |
| Hot Condenser | Y | Y | Y | Y |
| Power Failure | Y | Y | Y | Y |
| High/Low Voltage | Y | N/A | N/A | N/A |
| Sensor Error | Y | Y | Y | Y |
| Low Battery | Y | Y | Y | Y |
| High Ambient Temp | Y | Y | Y | Y |
| Door Ajar | Y | Y | Y | Y |
| Caster | Y | Y | Y | Y |
| Foot | Y | Y | Y | Y |
| Test Hole | Y | Y | Y | Y |
| Shelves/Inner Doors | 3/2 | 3/4 | 3/4 | 3/4 |
| Temperature Recorder | Optional | Optional | Optional | Optional |
| USB Interface | Y | Y | Y | Y |