Type | SKU | Price |
---|---|---|
Non-refrigerated | OH:30553037 |
$8,929
|
Refrigerated | OH:30553103 |
$12,604
|
Frontier 5000 Multi Pro Centrifuges are designed for universal use in research, industrial & clinical laboratories, and can be combined with our rotors & accessories for customized use in specific applications. Available in 11 models with capacities from 0.2 ml to 4 × 1000 ml - and feature high-speed performance at maximum volume, automatic rotor identification and safety features - these multi-purpose centrifuges are a must for any lab.
Features:
Rotors sold separately. See below for options.
RPM | 16,000 |
RCF | 24,325 / R-version: 26,331 g |
Refrigeration | Model Dependent |
Capacity | 4 x 750 ml |
Warranty (Years) | 2 |
Specs | FC5916 | FC5916R |
Speed Range | 200 rpm – 16,000 rpm | 200 rpm – 16,000 rpm |
Maximum Relative Centrifuge Force (x g) | 24,325 g | 26,331 g |
Maximum Capacity(Rotor) | 4 x 750 ml | 4 x 750 ml |
Refrigeration Range | N/A | -4 °F – 104 °F (-20 °C – 40 °C) |
Program memories | 99 | 99 |
Rotor In Package | Not applicable | Not applicable |
Acceleration Gear | 10 | 10 |
Deceleration Gear | 10 | 10 |
Dimensions | 26.4 in x 15.4 in x 21.3 in (670 mm x 390 mm x 540 mm) (LxHxW) | 26.4 in x 15.4 in x 28.7 in (670 mm x 390 mm x 730 mm) (LxHxW) |
Display | 2-line, backlit LCD | 2-line, backlit LCD |
Lid lock | Motor driven | Motor driven |
Net Weight | 187 lb (85 kg) | 260 lb (118 kg) |
Noise Level | ≤63±2 dB(A) | ≤63±2 dB(A) |
Power | AC Adapter (Included) | AC Adapter (Included) |
Power Consumption | 680 W | 1,750 W |
Pre-cool time | Not applicable | From room temperature to 4℃ < 10min |
Rotor Compatibility | Angle 4 x 85ml RB ID Hi; Angle 12 x 15 ml RB/FA ID; Angle 6 x 250 ml FB ID; Angle 24 x 1.5 / 2.0 ml ID Sealable; Angle 6 x 50 ml RB ID Hi; Swing out 4 x 100 ml ID; Angle 12 x 1.5 / 2.0 ml ID; Angle 4 x 8-w PCR Strip ID; Angle 44 x 1.5 / 2.0 ml ID; Swing out 4x750ml ID Sealable; Swing out 4 x 100 ml ID Sealable; Angle 6 x 85 ml RB ID; Angle 24 x 1.5 / 2.0 ml ID; Rotor Angle 4x500ml ID; Angle 6 x 85 ml RB ID Hi; Angle 30 x 15 ml RB/FA ID; Angle 30 x 1.5 / 2.0 ml ID Sealable; Angle 10 x 50 ml FA ID; Angle 64 x 0.5 ml ID; Angle 20 x 10 ml RB ID Hi; Angle 6 x 50 ml RB/FA ID; Swing out 2 x 3MTP ID | Angle 4 x 85ml RB ID Hi; Angle 12 x 15 ml RB/FA ID; Angle 6 x 250 ml FB ID; Angle 24 x 1.5 / 2.0 ml ID Sealable; Angle 6 x 50 ml RB ID Hi; Swing out 4 x 100 ml ID; Angle 12 x 1.5 / 2.0 ml ID; Angle 4 x 8-w PCR Strip ID; Angle 44 x 1.5 / 2.0 ml ID; Swing out 4x750ml ID Sealable; Swing out 4 x 100 ml ID Sealable; Angle 6 x 85 ml RB ID; Angle 24 x 1.5 / 2.0 ml ID; Rotor Angle 4x500ml ID; Angle 6 x 85 ml RB ID Hi; Angle 30 x 15 ml RB/FA ID; Angle 30 x 1.5 / 2.0 ml ID Sealable; Angle 10 x 50 ml FA ID; Angle 64 x 0.5 ml ID; Angle 20 x 10 ml RB ID Hi; Angle 6 x 50 ml RB/FA ID; Swing out 2 x 3MTP ID |
Rotor Recognition Method | Auto | Auto |
Running Time | Continous; 10 sec to 99 h 59 min 59 sec; Quickspin | Continous; 10 sec to 99 h 59 min 59 sec; Quickspin |
Safety Certification | CE; FCC | CE; FCC |
Working Environment | 41°F - 95 °F, 80%RH, non-condensing (5°C – 35°C, 80%RH, non-condensing) | 41°F - 95 °F, 80%RH, non-condensing (5°C – 35°C, 80%RH, non-condensing) |